I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
100-C Boonton7 62.528 9CAMPL Mut.Cond.750. Triode Sect.
100310 2060 0E0Z4 See note D.
10032 9060 0E0Z4 See note D.
10034 800 0ENOTHING Check for shorts
100512 1068 0G0Z4 See note D.
10051 126.368 0G0Z4 See note D.
10063 71.568 0A0Z4 See note D.
10062 71.568 0A0Z4 See note D.
10078 3062 0E0Z4 Shorts on 4 and 5.
10078 21.162 0E0Z4 Shorts on 4 and 5.
101D2 104.339 25AAMPL Insert tube in socket with pin on base away from operator.
101F2 104.341 26AAMPL Insert tube in socket with pin on base away from operator.
101FA2 104.360 35AAMPL Minimum value of 1100.
101J2 104.341 26AAMPL Insert tube in socket with pin on base away from operator.
102-A Boonton2 102.559 50AAMPL Mut.Cond.1850.
102D2 10240 23AAMPL Minimum value of 360.
102E2 10240 23AAMPL Minimum value of 360.
102F2 10240 23AAMPL Minimum value of 430.
102G2 10240 23AAMPL Minimum value of 360.
104D2 104.360 60AAMPL Minimum value of 830.
10Y2 107.550 32AAMPL (AKA 10 Special)
112A2 10557 36AAMPL Mut.Cond.1650.
114B7 51.543 25FAMPL See Note D. Connect right cap to upper right contact of A socket with lead provided. Connect grid lead to left cap.
117L7/M75 811740 0ERECT. STD. See note D.
117L7/M72 811772 30EAMPL Mut.Cond.6000. Shorts on 1, 4, and 5.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.

<< First  . . .    < Prev      1 [2] 3 4 5 6      Next >    . . .  Last >>




Last modified: Jun 5, 2026 20:40
Cape Old Radio - Since Nov, 1996
1996 - 2026 © Carlos Eduardo Lazarini da Fonseca