Cape Old Radio
: Home : : cor_seco78.php?currentpage=47 :
Search Radio by Make, Model, Year, and/or Country.
Click to Expand/Collapse OptionHome
Click to Expand/Collapse OptionNew on Site
Click to Expand/Collapse OptionImage Index
Click to Expand/Collapse OptionContact
Click to Expand/Collapse OptionBeitman's & Rider's
Click to Expand/Collapse OptionUseful Links
Click to Expand/Collapse OptionTechnical Info
Click to Expand/Collapse OptionTube/Valve
Click to Expand/Collapse OptionRadio Collection

SECO 78 Tube Tester




Select or type a tube name to get specific settings for the Eico 635 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A

ID Tube IC Fil. Volts R Load L Notes
1151 17H3 17 F 45 Z
1152 17L6 17 D 40 X
1153 17R5 17 B 40 Z
1154 17Z3 17 E 50
1155 18A5 18 A 45 X
1156 18AK5 18 A 40
1157 18AQ5 18 A 60 X
1158 18FW6 18 A 40
1159 18FX6 18 A 45
1160 18FY6 18 A 60
1161 18FY6 18 D 100
1162 18FY6 18 G 100
1163 18GD6 18 A 45
1164 18GE6 18 A 60
1165 18GE6 18 D 100
1166 18GE6 18 G 100
1167 18J6 18 D 40
1168 18J6 18 G 40
1169 19AQ5 19 A 60 X
1170 19AU4 19 D 50
1171 19BG6 19 D 50 X
1172 19C8 19 F 65
1173 19C8 19 B 45
1174 19C8 19 A 45
1175 19C8 19 D 45
OPERATING INSTRUCTIONS
BEFORE YOU TEST
1. Set the "Function Switch" to its mid-position.
2. Set the Switch "L" to position marked "NORMAL"
3. Push the slide switch to "ON" position.
4. Allow a half minute for the tester warm up.
5. The meter pointer should rise to renter scale to the mark labeled "Line Adjust". Adjust control on the panel marked "Line Adjust" with a small screwdriver, if necessary.
TESTING
6. CAUTION: DO NOT INSERT THE TUBE INTO ITS SOCKET UNTIL ALL CONTROLS ARE PROPERLY SET UP.
7. Locate the tube to be tested on the set-up card. Example: Tube Type = 6AU4 -> Fil. V. = 6 -> Sw. "R" = D -> Load = 50 -> Sw. "L" = Leave in "normal" unless indicated by X, Y, or Z
8. Set up the controls as indicated.
9. Insert the tube in its socket. There-are two nine-pin sockets. The one at the tipper left is only used when indicated in the tube set-up.
10. Place the cap clip on top of the tube if one is used.
11. As the tube warms up the meter pointer will gradually read into the "GOOD" area on the right side of the scale. REJECT THE TUBE IF IT READS IN THE RED "REPLACE" area.
12. Push the "Function Switch" forward to the position marked "GCT SHORTS AND LEAKAGE" and tap the tube gently. A good tube should read in the "GOOD" area at the left end of the meter scale. REJECT THE TUBE IF THE POINTER JUMPS INTO THE RED AREA OR STAYS IN THE RED AREA.
13. Tubes having two or more entries on the set-up require more than one test. Set controls as indicated and proceed to test again. NOTE: on many types having two entries it is only necessary to move the SELECTOR SWITCH "R".
14. If it is desired to check a tube for filament continuity ONLY then pull the "FUNCTION" switch to position marked "FILAMENT CONTINUITY". The meter should read in the "GOOD" on the right side of the meter scale if continuity exists.
15. If an asterisk (*) appears opposite the tube set-up, this means that an inter-connection exists in the tube which cannot be isolated with lever switch "L". Such interconnections will indicate the same as a short between these pins and cause the meter to read in the red. Consult the tube manual if necessary.


<< First  . . .    < Prev      42 43 44 45 46 [47] 48 49 50 51      Next >    . . .  Last >>




Last modified: Jun 5, 2026 20:40
Cape Old Radio - Since Nov, 1996
1996 - 2026 © Carlos Eduardo Lazarini da Fonseca