| Tube |
A |
B |
Filament |
L |
R |
Socket |
Press |
Notes |
|---|
| 1AF5 | 5 |
6 | 1.5 | 0 |
19 | H | AMPL |
Mut.Cond. 500. Pent. Section |
| 1B3 | 7 |
1 | 1.1 | 0 |
0 | E | RECT. STD. |
Shorts on 3,4, and 5. See note A. OK over 300. See note D. |
| 1B3 / 8016 | 7 |
1 | 1.1 | 0 |
0 | E | RECT. STD. |
OK over 300. See note D. |
| 1B4 | 2 |
5 | 2 | 18 |
29 | A | AMPL |
Mut.Cond.640. |
| 1B4P | 2 |
5 | 2 | 18 |
29 | A | AMPL |
|
| 1B5 | 12 |
3 | 2 | 0 |
0 | C | DIODE |
|
| 1B5 | 10 |
8 | 2 | 0 |
0 | C | DIODE |
|
| 1B5 | 7 |
8 | 2 | 60 |
23 | C | AMPL |
Mut.Cond.475. OK over 380 |
| 1B5 / 25S | 12 |
3 | 2 | 0 |
0 | C | DIODE |
|
| 1B5 / 25S | 10 |
8 | 2 | 0 |
0 | C | DIODE |
|
| 1B5 / 25S | 7 |
8 | 2 | 60 |
23 | C | AMPL |
OK over 380 |
| 1B7 | 12 |
7 | 1.5 | 60 |
38 | E | AMPL |
Mut.Cond.300. Osc.Sect. OK over 240 on 3000 scale.. |
| 1B7 | 7 |
7 | 1.5 | 32 |
20 | E | AMPL |
Mut.Cond.800. Pent.Section. |
| 1C | 1 |
5 | 2.5 | 40 |
0 | A | RECT. STD. |
|
| 1C | 4 |
5 | 2.5 | 40 |
0 | A | RECT. STD. |
|
| 1C21 | 10 |
2 | 0 | 0 |
0 | E | DIODE |
Meter indication is optained when FIL control is switched to 50. See note D. |
| 1C5 | 8 |
5 | 1.5 | 55 |
36 | E | AMPL |
Mut.Cond.1550. See note E. |
| 1C6 | 9 |
7 | 2 | 60 |
41 | C | AMPL |
Mut.Cond.300. Osc.Sect. OK over 240 on 3000 scale. See note D. |
| 1C6 | 1 |
5 | 2 | 20 |
24 | C | AMPL |
Mut.Cond.650. See note D. |
| 1C7 | 12 |
7 | 2 | 60 |
41 | E | AMPL |
Mut.Cond.300. Osc.Sect. OK over 240 on 3000 scale. See note D. |
| 1C7 | 2 |
5 | 2 | 20 |
24 | E | AMPL |
Mut.Cond.650. See note D. |
| 1D5G | 2 |
5 | 2 | 27 |
24 | E | AMPL |
Mut.Cond. 750. |
| 1D5GP | 2 |
5 | 2 | 27 |
24 | E | AMPL |
|
| 1D7G | 12 |
7 | 2 | 60 |
35 | E | AMPL |
Mut.Cond.200. OK over 160. See note D. |
| 1D7G | 2 |
5 | 2 | 0 |
29 | E | AMPL |
Mut.Cond.750. See note D. |
| Important |
|
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002.
A great compilation by Nolam E. Lee. |
|
Note A: The plate cap of the tube under test should be connected to the upper left
contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose. |
|
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket;
use the lead provided. Connect the grid lead to the remaining cap on the tube. |
|
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either
Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate. |
|
Note D: This test is only a partial indication of a good tube. A complete test is only possible
when using equipment. |
|
Note E: Do not tap on this tube when testing for short because damage to the tube may result. |
|
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide. |
<< First . . .   < Prev   7 8 9 10 11 [12] 13 14 15 16   Next > . . .  Last >>