I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
6J88 56.341 15EAMPL Mut.Cond.1000. See note D.
6K57 56.340 17EAMPL Mut.Cond.1000.
6K68 56.355 28EAMPL Mut.Cond.1600.
6K78 56.354 16EAMPL Mut.Cond.1450.
6K88 56.341 9EAMPL Mut.Cond.1000. See note D.
6K811 56.363 9EAMPL Mut.Cond.2400. See note D.
6L57 56.356 22EAMPL Mut.Cond.1500.
6L68 56.363 20EAMPL Mut.Cond.5000. Set MICROMHOS switch to 6000.
6L78 56.320 22EAMPL Mut.Cond.650. See note D.
6L71 96.320 19EAMPL Mut.Cond.650. See note D.
6N47 56.371 17LAMPL
6N512 26.30 0CAMPL Eye closed.
6N512 36.30 0CAMPL Eye open.
6N68 56.352 0EAMPL Mut.Cond.1500.
6N72 96.353 10EAMPL Mut.Cond.1500.
6N712 56.353 10EAMPL Mut.Cond.1500.
6P57 56.353 24EAMPL Mut.Cond.1450.
6P76 126.360 23EAMPL Mut.Cond.450. OK over 360.
6P73 126.345 23EAMPL Mut.Cond.1100.
6Q57 56.340 80ERECT. STD. Good tube indicates between 40 and 50 when R is rotated counterclockwise. See note D.
6Q67 26.30 0EDIODE
6Q67 56.340 14EAMPL Mut.Cond.1000.
6Q710 26.30 0EDIODE
6Q710 56.30 0EDIODE
6Q77 56.333 14EAMPL Mut.Cond.800.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.