I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
6AQ64 86.30 82KDIODE
6AQ612 26.345 5KAMPL Mut.Cond.1150.
6AQ72 86.30 0GDIODE Diode Section
6AQ79 26.340 0GAMPL Mut.Cond.1000. Triode Section.
6AR51 96.348 35KAMPL Mut.Cond.1600.
6AR68 56.371 36EAMPL Use Adapter # 3.
6AS61 96.342 15KAMPL Mut.Cond.1750.
6AT61 86.30 0KDIODE
6AT64 86.30 0KDIODE
6AT611 46.347 15KAMPL Mut.Cond.1200.
6AU412 46.340 0GRECT. STD.
6AU61 96.362 16KAMPL Mut.Cond.2300.
6AV62 86.30 0KDIODE Diode No. 2
6AV63 86.30 0KDIODE Diode No. 1
6AV612 26.350 10KAMPL Mut.Cond.1250. Triode Section.
6AX47 16.340 0GRECT. STD.
6AX510 26.333 0ERECT. STD. Plate No. 2.
6AX52 96.333 0ERECT. STD. Plate No. 1.
6AX68 76.340 0ERECT. STD. Plate No. 2.
6AX67 26.340 0ERECT. STD. Plate No. 1.
6B47 56.367 55EAMPL Mut.Cond.3000.
6B58 56.352 0CAMPL Mut.Cond.1500.
6B610 26.30 0EDIODE
6B610 56.30 0EDIODE
6B67 56.328 9EAMPL Mut.Cond.750.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.