I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
6DC67 96.364 21KAMPL Mut.Cond.2500.
6DE61 96.362 18KAMPL Mut.Cond.2200.
6E512 26.30 0CAMPL Eye closed.
6E512 36.30 0CAMPL Eye open.
6E612 56.352 23DAMPL Mut.Cond.1400.
6E61 56.352 23DAMPL Mut.Cond.1400.
6E77 66.355 20DAMPL Mut.Cond.1500.
6F510 56.343 10EAMPL Mut.Cond.1000.
6F68 56.360 24EAMPL Mut.Cond.2000.
6F710 66.360 23DAMPL Mut.Cond.450. OK over 360.
6F77 66.345 23DAMPL Mut.Cond.1100.
6F811 76.360 13EAMPL Mut.Cond.2000. Plate No. 2.
6F88 76.360 13EAMPL Mut.Cond.2000. Plate No. 1.
6G512 26.30 0CAMPL Eye closed.
6G512 36.30 0CAMPL Eye open.
6G68 56.361 19EAMPL Mut.Cond.2100.
6H46T4 86.350 0EDIODE
6H67 56.350 0EDIODE
6H67 26.350 0EDIODE
6J48 46.374 0LAMPL Mut.Cond.6000. Short on 3.
6J57 56.360 24EAMPL Mut.Cond.2000.
6J611 86.369 11KAMPL Mut.Cond.5000. See note D.
6J61 26.369 11KAMPL Mut.Cond.5000. See note D.
6J71 96.348 18EAMPL Mut.Cond.1225.
6J811 56.30 25EAMPL Mut.Cond.500. See note D.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.