Cape Old Radio
: Home : : cor_i177.php?currentpage=18 :
Search Radio by Make, Model, Year, and/or Country.
Click to Expand/Collapse OptionHome
Click to Expand/Collapse OptionNew on Site
Click to Expand/Collapse OptionImage Index
Click to Expand/Collapse OptionContact
Click to Expand/Collapse OptionBeitman's & Rider's
Click to Expand/Collapse OptionUseful Links
Click to Expand/Collapse OptionTechnical Info
Click to Expand/Collapse OptionTube/Valve
Click to Expand/Collapse OptionRadio Collection

I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
262A2 61015 25AAMPL
262B2 61015 25AAMPL
26C63 8250 0KDIODE Diode No. 2
26C67 10250 0KDIODE Diode No. 1
26C611 22557 9KAMPL Mut.Cond.1700. Triode Section
26D67 92552 9KAMPL Mut.Cond.1425. Osc. Section
26D68 52555 15KAMPL Mut.Cond.1600. Ampl. Section.
26E68 02574 36EAMPL Mut.Cond.6000. Read in good scale.
26E6W8 52560 42EAMPL Allow tube 60 seconds to warm-up. Set MICROMHOS switch at 6000.
271 62.540 34BAMPL Mut.Cond.1000.
27 Special1 62.540 34BAMPL Mut.Cond.1000.
271A1 6560 30AAMPL Minimum Value of 1580.
272A1 61046 26BAMPL
274A2 7535 0ARECT. STD. See note D.
274A3 7535 0ARECT. STD. See note D.
274B4 11535 0ERECT. STD. See note D.
274B5 11535 0ERECT. STD. See note D.
275A2 10554 70AAMPL
27HM1 62.553 29BAMPL Mut.Cond.1450.
283A7 6249 10BAMPL
285A7 6260 30BAMPL Minimum Value of 660.
28D73 62560 12FAMPL Mut.Cond.2000. Plate #2.
28D78 12560 12FAMPL Mut.Cond.2000. Plate #1.
298 62.50 19CAMPL Mut. Cont.500. No. 2. Grid.
298 82.50 19CAMPL Mut.Cond.500. No. 1. Grid.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.

<< First  . . .    < Prev      13 14 15 16 17 [18] 19 20 21 22      Next >    . . .  Last >>




Last modified: Jun 5, 2026 20:40
Cape Old Radio - Since Nov, 1996
1996 - 2026 © Carlos Eduardo Lazarini da Fonseca