Cape Old Radio
: Home : : cor_i177.php?currentpage=20 :
Search Radio by Make, Model, Year, and/or Country.
Click to Expand/Collapse OptionHome
Click to Expand/Collapse OptionNew on Site
Click to Expand/Collapse OptionImage Index
Click to Expand/Collapse OptionContact
Click to Expand/Collapse OptionBeitman's & Rider's
Click to Expand/Collapse OptionUseful Links
Click to Expand/Collapse OptionTechnical Info
Click to Expand/Collapse OptionTube/Valve
Click to Expand/Collapse OptionRadio Collection

I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
2C347 56.350 30DAMPL Connect left plate cap to upper right contact on A socket with lead provided.
2C341 56.350 30DAMPL Connect right plate cap to upper right contact on A socket with lead provided.
2C411 92.540 80HRECT. STD. Tube strikes at approximately 60 on R when this control is rotated counterclockwise. See note D.
2C452 107.562 30AAMPL Mut.Cond.2200.
2C539 56.30 0EAMPL Connect plate cap to upper center contact on D socket with lead provided. OK over 900. See bote D.
2D214 86.340 80KRECT. STD. Good tube strikes between 25 and 30 on R when this control is rotated counterclockwise. Shorts on 2 and 3. See note D.
2E2212 16.371 0BAMPL Mut.Cond.4000. See note A.
2E258 56.367 0EAMPL Mut.Cond.3000. Connect cap to upper right-hand contact of B socket with lead provided.
2E512 22.50 0CAMPL Eye closed.
2E512 32.50 0CAMPL Eye open.
2G512 26.30 0CAMPL Eye closed.
2G512 36.30 0CAMPL Eye open.
2V37 12.50 0ERECT. STD. OK over 500. See notes A and D.
2W34 112.533 0ERECT. STD.
2X27 12.50 0ARECT. STD. OK over 1000. See notes A and D.
2X2A7 12.50 0ARECT. STD. OK over 1000. See notes A and D.
2Z22 72.535 0ARECT. STD. See note D.
302 10243 30AAMPL Mut.Cond.1025.
302 10236 33AAMPL Mut.Cond.900.
300B2 8560 48AAMPL Set MICROMHOS switch at 6000. OK over 1600.
307A12 1569 30BAMPL See note A.
312 10235 53AAMPL Mut.Cond.925.
310A2 51050 16CAMPL
310B2 51044 20CAMPL
311A7 61061 33BAMPL
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.

<< First  . . .    < Prev      15 16 17 18 19 [20] 21 22 23 24      Next >    . . .  Last >>




Last modified: Jun 5, 2026 20:40
Cape Old Radio - Since Nov, 1996
1996 - 2026 © Carlos Eduardo Lazarini da Fonseca