| Tube |
A |
B |
Filament |
L |
R |
Socket |
Press |
Notes |
|---|
| HD51 | 4 |
4 | 0 | 0 |
0 | H | GAS No. 1 |
OK over 200. Shorts on 4 and 5. See note D. |
| HD52 | 4 |
4 | 0 | 30 |
0 | H | GAS No. 1 |
OK over 200. Shorts on 4 and 5. See note D. |
| HK24G | 3 |
2 | 6.3 | 30 |
20 | A | AMPL |
Connect top terminal of tube under test to upper contact of 5 pin (B) socket. Use separate lead provided. Connect side t |
| HY113 | 7 |
5 | 1.5 | 0 |
40 | O | AMPL |
Mut.Cond.500. |
| HY114B | 10 |
5 | 1.5 | 43 |
15 | E | AMPL |
Mut.Cond.1100.Connect grid to upper left contact of 6-pin socket. Connect plate to upper right contact of 6-pin socket. |
| HY115 | 7 |
5 | 1.5 | 60 |
32 | O | AMPL |
Mut.cond.370.OK over 290. |
| HY123 | 7 |
5 | 1.5 | 0 |
45 | ? | AMPL |
Mut.Cond.370.OK over 290. |
| HY125 | 7 |
5 | 1.5 | 60 |
45 | O | AMPL |
Mut.Cond.450.OK over 360. |
| HY1269 | 12 |
1 | 12.6 | 70 |
24 | B | AMPL |
Mut.Cond.4000. See note A. Shorts on 2 and 5. |
| HY145 | 7 |
5 | 1.5 | 60 |
32 | O | AMPL |
Mut.Cond.370.OK over 290. |
| HY155 | 7 |
5 | 1.5 | 60 |
45 | O | AMPL |
Mut.Cond.450.OK over 360. |
| HY69 | 4 |
7 | 6.3 | 70 |
27 | B | AMPL |
Mut.Cond.3500. Connect plate to top contact of 7-pin socket. |
| KR2 | 1 |
5 | 2.5 | 40 |
0 | A | RECT. STD. |
|
| KR20 | 8 |
6 | 2.5 | 2 |
30 | C | AMPL |
Mut.Cond.500. No.2 Grid. |
| KR20 | 8 |
8 | 2.5 | 2 |
30 | C | AMPL |
Mut.Cond.500. No.1 Grid. |
| KR22 | 8 |
6 | 6.3 | 2 |
30 | C | AMPL |
Mut.Cond.500. No.2 Grid. |
| KR22 | 8 |
8 | 6.3 | 2 |
30 | C | AMPL |
Mut.Cond.500. No.1 Grid. |
| KR25 | 8 |
5 | 2.5 | 57 |
28 | C | AMPL |
Mut.Cond. 1750. |
| KR28 | 5 |
1 | 6.3 | 40 |
0 | B | RECT. STD. |
Plate No.2. |
| KR28 | 7 |
7 | 6.3 | 40 |
0 | B | RECT. STD. |
Plate No.1. |
| KR5 | 1 |
5 | 6.3 | 60 |
23 | B | AMPL |
Mut.Cond.2000. |
| KT63 | 8 |
5 | 6.3 | 60 |
24 | E | AMPL |
Mut.Cond.2000. |
| KT66 | 8 |
5 | 6.3 | 74 |
18 | E | AMPL |
Mut.Cond.6300. |
| LA | 1 |
5 | 6.3 | 60 |
23 | B | AMPL |
Mut.Cond.2000. |
| M1060 | 9 |
5 | 6.3 | 0 |
0 | E | AMPL |
Connect plate cap to upper center contact on D socket with lead provided. OK over 900. See bote D. |
| Important |
|
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002.
A great compilation by Nolam E. Lee. |
|
Note A: The plate cap of the tube under test should be connected to the upper left
contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose. |
|
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket;
use the lead provided. Connect the grid lead to the remaining cap on the tube. |
|
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either
Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate. |
|
Note D: This test is only a partial indication of a good tube. A complete test is only possible
when using equipment. |
|
Note E: Do not tap on this tube when testing for short because damage to the tube may result. |
|
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide. |
<< First . . .   < Prev   54 55 56 57 58 [59] 60 61 62   Next > . . .  Last >>