| Tube |
A |
B |
Filament |
L |
R |
Socket |
Press |
Notes |
|---|
| C182A | 2 |
10 | 5 | 53 |
65 | A | AMPL |
Mut.Cond.1500. |
| C373 | 2 |
10 | 3 | 42 |
41 | ? | AMPL |
Mut.Cond.1000. |
| C686 | 1 |
6 | 3 | 60 |
35 | ? | AMPL |
Mut.Cond.450. MICROMHOS only. OK over 360 on 3000 scale. |
| CK611 | 7 |
5 | 6.3 | 71 |
17 | L | AMPL |
|
| CK612 | 1 |
9 | 6.3 | 75 |
9 | K | AMPL |
Mut.Cond.8000. Shorts on 4 and 5. |
| CV18 (Brit.) | 7 |
5 | 6.3 | 50 |
30 | D | AMPL |
Connect left plate cap to upper right contact on A socket with lead provided. |
| CV18 (Brit.) | 1 |
5 | 6.3 | 50 |
30 | D | AMPL |
Connect right plate cap to upper right contact on A socket with lead provided. |
| D-10 | 7 |
2 | 6.3 | 54 |
15 | E | AMPL |
Mut.Cond.1500. See note A. |
| D25 | 8 |
5 | 6.3 | 67 |
0 | E | AMPL |
Mut.Cond.3000. Connect cap to upper right-hand contact of B socket with lead provided. |
| D27 | 4 |
2 | 6.3 | 60 |
0 | K | DIODE |
Shorts on 2 and 3. |
| D27 | 9 |
2 | 6.3 | 60 |
0 | K | DIODE |
Shorts on 2 and 3. |
| D28 | 4 |
8 | 6.3 | 0 |
82 | K | DIODE |
|
| D28 | 12 |
2 | 6.3 | 45 |
5 | K | AMPL |
Mut.Cond.1150. |
| D86326 | 2 |
10 | 4.3 | 39 |
25 | A | AMPL |
Insert tube in socket with pin on base away from operator. |
| D86327 | 2 |
10 | 4.3 | 60 |
60 | A | AMPL |
Minimum value of 830. |
| DE1 | 1 |
6 | 2.5 | 40 |
34 | B | AMPL |
Mut.Cond.1000. |
| DH63 (Brit.) | 10 |
2 | 6.3 | 0 |
0 | E | DIODE |
|
| DH63 (Brit.) | 10 |
5 | 6.3 | 0 |
0 | E | DIODE |
|
| DH63 (Brit.) | 7 |
5 | 6.3 | 33 |
14 | E | AMPL |
Mut.Cond.800. |
| DT-70 | 12 |
1 | 6.3 | 71 |
0 | B | AMPL |
Mut.Cond.4000. See note A. |
| DT153 | 2 |
5 | 1.5 | 35 |
12 | H | AMPL |
Shorts on 4 and 5. See note E. |
| E1148 | 7 |
2 | 6.3 | 62 |
10 | ? | AMPL |
Mut.Cond.2200.Upper cap = plate. Lower cap = grid. |
| E82CC | 4 |
2 | 12.6 | 60 |
25 | E | AMPL |
Use adapter #6 for triode #2. |
| E82CC | 4 |
2 | 12.6 | 60 |
25 | E | AMPL |
Use adapter #5 for triode #1. |
| E90Z | 6 |
5 | 6.3 | 35 |
0 | K | RECT. STD. |
Plate No. 2. See note D. |
| Important |
|
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002.
A great compilation by Nolam E. Lee. |
|
Note A: The plate cap of the tube under test should be connected to the upper left
contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose. |
|
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket;
use the lead provided. Connect the grid lead to the remaining cap on the tube. |
|
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either
Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate. |
|
Note D: This test is only a partial indication of a good tube. A complete test is only possible
when using equipment. |
|
Note E: Do not tap on this tube when testing for short because damage to the tube may result. |
|
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide. |
<< First . . .   < Prev   52 53 54 55 56 [57] 58 59 60 61   Next > . . .  Last >>