| Tube |
A |
B |
Filament |
L |
R |
Socket |
Press |
Notes |
|---|
| 56 | 1 |
6 | 2.5 | 53 |
26 | B | AMPL |
Mut.Cond.1450. |
| 5610 | 8 |
10 | 6.3 | 70 |
22 | L | AMPL |
Mut.Cond.4000. |
| 5654 | 1 |
9 | 6.3 | 55 |
20 | K | AMPL |
Mut.Cond.1500. Shorts on 4 and 5. |
| 5663 | 12 |
2 | 6.3 | 40 |
80 | K | RECT. STD. |
Tube strikes at approximately 25 on R when this control is turned counter clockwise. See note D. |
| 5679 | 11 |
5 | 6.3 | 40 |
0 | F | DIODE |
Diode No. 2 Shorts on 2, 3, 4, and 5. |
| 5679 | 8 |
5 | 6.3 | 40 |
0 | F | DIODE |
Diode No. 1 Shorts on 1, 2, 3, 4, and 5. |
| 5691 | 10 |
4 | 6.3 | 53 |
0 | G | AMPL |
Mut.Cond.1400. Triode No.2. Shorts on 2 and 3. |
| 5691 | 4 |
1 | 6.3 | 36 |
0 | G | AMPL |
Mut.Cond.900. Triode No.1. |
| 5692 | 10 |
4 | 6.3 | 56 |
24 | G | AMPL |
Mut.Cond.1650.Triode No.2. Shorts on 2 and 3. |
| 5692 | 4 |
1 | 6.3 | 56 |
24 | G | AMPL |
Mut.Cond.1650.Triode No.1. |
| 5694 | 12 |
5 | 6.3 | 60 |
0 | E | AMPL |
Mut.Cond.2000.Triode No.2. Shorts on 1,4, and 5. |
| 5694 | 2 |
9 | 6.3 | 60 |
0 | E | AMPL |
Mut.Cond.2000.Triode No.1. Shorts on 4 and 5. |
| 57 | 2 |
5 | 2.5 | 48 |
17 | C | AMPL |
Mut.Cond.1225. |
| 5725 | 1 |
9 | 6.3 | 42 |
15 | K | AMPL |
|
| 5726 | 4 |
2 | 6.3 | 60 |
0 | K | DIODE |
Shorts on 2 and 3. |
| 5726 | 9 |
2 | 6.3 | 60 |
0 | K | DIODE |
Shorts on 2 and 3. |
| 5729 | 4 |
8 | 6.3 | 40 |
80 | K | RECT. STD. |
Good tube strikes between 25 and 30 on R when this control is rotated counterclockwise. Shorts on 2 and 3. See note D. |
| 5731 | 9 |
6 | 6.3 | 52 |
24 | M | AMPL |
Mut.Cond.1500. |
| 5732 | 8 |
5 | 6.3 | 54 |
16 | E | AMPL |
Mut.Cond.1450. |
| 5742 | 2 |
8 | 5 | 25 |
12 | A | AMPL |
Mut.Cond.750. |
| 5749 | 7 |
9 | 6.3 | 70 |
0 | K | AMPL |
|
| 5750 | 7 |
9 | 6.3 | 55 |
23 | K | AMPL |
Mut.Cond.1600. |
| 57A | 2 |
5 | 6.3 | 48 |
17 | C | AMPL |
Mut.Cond.1225. |
| 57AS | 2 |
5 | 6.3 | 48 |
17 | C | AMPL |
Mut.Cond.1225. |
| 57S | 2 |
5 | 2.5 | 48 |
17 | C | AMPL |
Mut.Cond.1225. |
| Important |
|
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002.
A great compilation by Nolam E. Lee. |
|
Note A: The plate cap of the tube under test should be connected to the upper left
contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose. |
|
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket;
use the lead provided. Connect the grid lead to the remaining cap on the tube. |
|
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either
Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate. |
|
Note D: This test is only a partial indication of a good tube. A complete test is only possible
when using equipment. |
|
Note E: Do not tap on this tube when testing for short because damage to the tube may result. |
|
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide. |
<< First . . .   < Prev   27 28 29 30 31 [32] 33 34 35 36   Next > . . .  Last >>