| Tube |
A |
B |
Filament |
L |
R |
Socket |
Press |
Notes |
|---|
| 3E6 | 6 |
2 | 3 | 55 |
16 | F | AMPL |
Mut.Cond.1600. Shorts on 4 and 5. |
| 3LE4 | 6 |
2 | 2.5 | 45 |
45 | F | AMPL |
Mut.Cond.1100. Short on 1. |
| 3LF4 | 6 |
2 | 3 | 62 |
20 | F | AMPL |
Mut.Cond.1500. Shorts on 1. See note E. |
| 3Q4 | 4 |
2 | 3 | 50 |
35 | E | AMPL |
Mut.Cond.850. See note E. Use adapter #4. |
| 3Q5 | 8 |
5 | 3 | 58 |
31 | E | AMPL |
Mut.Cond.1800. Shorts on 4 and 5. See note E. |
| 3S4 | 4 |
6 | 3 | 31 |
0 | H | DIODE |
Mut.Cond.750. Shorts on 3, 4, and 5. See note E. |
| 3V4 | 1 |
7 | 3 | 56 |
28 | H | AMPL |
Mut.Cond.1650. Shorts on 4 and 5. See note E. |
| 40 | 2 |
10 | 5 | 60 |
26 | A | AMPL |
Mut.Cond.200. OK over 160. |
| 401 | 2 |
10 | 3 | 42 |
41 | A | AMPL |
Mut.Cond. 1000. |
| 401A DeForest | 2 |
10 | 5 | 26 |
39 | A | AMPL |
Mut.Cond. 725. |
| 403 | 2 |
10 | 3 | 46 |
72 | A | AMPL |
Mut.Cond.1200. |
| 403A | 1 |
9 | 6.3 | 55 |
20 | K | AMPL |
Mut.Cond.1500. Shorts on 4 and 5. |
| 40Z5/45Z5 | 1 |
3 | 0 | 40 |
0 | E | RECT. STD. |
Shorts on 1, 2, 3, 4, and 5. See note D. |
| 40Z5/45Z5 | 11 |
1 | 35 | 40 |
0 | E | RECT. STD. |
See note D. |
| 41 | 8 |
5 | 6.3 | 55 |
28 | C | AMPL |
Mut.Cond.1600. |
| 42 | 8 |
5 | 6.3 | 60 |
24 | C | AMPL |
Mut.Cond.2000. |
| 43 | 8 |
5 | 25 | 62 |
35 | C | AMPL |
Mut.Cond.2300. |
| 43M | 8 |
5 | 25 | 62 |
35 | E | AMPL |
Mut.Cond.2300. |
| 45 | 2 |
10 | 2.5 | 59 |
50 | A | AMPL |
Mut.Cond.1850. |
| 45Z3 | 10 |
2 | 35 | 40 |
0 | H | 117N7 AND RECTIFIER |
See note D. |
| 45Z5 | 1 |
3 | 0 | 40 |
0 | E | NOTHING |
Shorts on 1, 2, 3, 4, and 5. |
| 45Z5 | 11 |
1 | 35 | 40 |
0 | E | RECT. STD. |
See note D. |
| 46 | 1 |
5 | 2.5 | 60 |
25 | B | AMPL |
Mut.Cond.2000. |
| 47 | 1 |
5 | 2.5 | 60 |
18 | B | AMPL |
Mut.Cond.2000. |
| 48 | 8 |
5 | 25 | 60 |
48 | C | AMPL |
Mut.Cond.2000. |
| Important |
|
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002.
A great compilation by Nolam E. Lee. |
|
Note A: The plate cap of the tube under test should be connected to the upper left
contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose. |
|
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket;
use the lead provided. Connect the grid lead to the remaining cap on the tube. |
|
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either
Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate. |
|
Note D: This test is only a partial indication of a good tube. A complete test is only possible
when using equipment. |
|
Note E: Do not tap on this tube when testing for short because damage to the tube may result. |
|
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide. |
<< First . . .   < Prev   24 25 26 27 28 [29] 30 31 32 33   Next > . . .  Last >>