I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
382132 102.567 55AAMPL Mut.Cond.3000.
382158 52.560 24CAMPL Mut.Cond.2000.
3822710 32.50 0DDIODE Diode No. 2
3822710 62.50 0DDIODE Diode No. 1
382277 62.541 25DAMPL Mut.Cond.1000.
382339 36.342 28DAMPL Mut.Cond.1000.
382333 36.342 28DAMPL Mut.Cond.1000.
382369 7260 41CAMPL Mut.Cond.300. Osc.Sect. OK over 240 on 3000 scale. See note D.
382361 5220 24CAMPL Mut.Cond.650. See note D.
382507 1030 0GGAS No. 1 Shorts on 4 and 5. See note D.
3825512 82540 0CRECT. STD. See note D.
382557 82540 0CRECT. STD. See note D.
38266A7 1330 0ARECT. STD. See notes A and D. OK over 1500.
382677 12.535 0ARECT. STD. See notes A and D.
382744 5030 0AGAS No. 1 See note D.
382757 1050 0GGAS No. 1 Shorts on 4 and 5. See note D.
382907 1030 0GGAS No. 1 Shorts on 4 and 5.
384051 52.540 0ARECT. STD. See note D.
38565J7 56.360 24EAMPL Mut.Cond.2000.
38566H7 56.350 0EDIODE
38566H7 26.350 0EDIODE
38567K8 56.354 16EAMPL Mut.Cond.1450.
38567R10 26.30 0EDIODE
38567R10 56.30 0EDIODE
38567R7 56.360 17EAMPL Mut.Cond.1900.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.