I-177 Tube Tester




Select or type a tube name to get specific settings for the I-177 Tube Tester.


Sort columns values by clicking their titles - A → Z or Z → A


Tube A B Filament L R Socket Press Notes
582 52.554 20CAMPL Mut.Cond.1450.
58127 96.370 38KAMPL Mut.Cond.4300. Shorts on 4 and 5.
58144 212.660 25EAMPL Use adapter #6 for Triode #2.
58144 212.660 25EAMPL Use adapter #5 for Triode #1.
58248 52571 43EAMPL Mut.Cond.4000.
58397 52535 0ERECT. STD. See note D.
58397 22535 0ERECT. STD. See note D.
584411 86.366 13KAMPL Mut.Cond.3000.Triode No.2.
58441 26.366 13KAMPL Mut.Cond.3000.Triode No.1.
5852 107.553 50AAMPL Mut.Cond.1500.
585210 26.340 0ERECT. STD. See note D.
58528 56.340 0ERECT. STD. See note D.
5862 107.553 50AAMPL Mut.Cond.1500.
58818 56.363 20EAMPL Mut.Cond.5000.Set MICROMHOS switch to 6000.
58A/58AS2 56.354 20CAMPL Mut.Cond.1450.
598 82.560 18DAMPL Mut.Cond.2000.
59302 102.557 55AAMPL
59315 11540 0ERECT. STD. See note D.
59314 11540 0ERECT. STD. See note D.
59328 56.363 20EAMPL Set MICROMHOS switch at 6000.
59331 66.30 56BAMPL Special cap lead to right center of 6 pin (C) socket. OK over 500
59617 76.328 17EAMPL Mut.Cond.750. See note D.
59611 76.328 17EAMPL Mut.Cond.750. See note D.
59928 56.367 25EAMPL Mut.Cond.3000.
5AQ58 5570 17LAMPL Mut.Cond.3700.
Important
This I-177 data-base was created using data from I-177 beta 1.08 worksheet, from July 5, 2002. A great compilation by Nolam E. Lee.
Note A: The plate cap of the tube under test should be connected to the upper left contact of the 6-pin (C) socket. A 12-inch lead with clip and bananna plug is provided for this purpose.
Note B: Connect the plate cap (nearest the operator) to the upper left contact of the 6-pin (C) socket; use the lead provided. Connect the grid lead to the remaining cap on the tube.
Note C: Set the MICROMHOS switch at 6000 when testing this section if the tube tester bears either Order No. 27613-Phila-44-52 or 52346-Phila-45-10 on the nomenclature plate.
Note D: This test is only a partial indication of a good tube. A complete test is only possible when using equipment.
Note E: Do not tap on this tube when testing for short because damage to the tube may result.
Note F: The Mutual Conductance values listed are averages for new tubes and only for a guide.